A dormer bungalow in Ravenshead, from the roof down.
A 1940s or 1950s detached dormer bungalow on a Ravenshead street of individual homes set among mature pines. It was extended around 2005 with a rear ground floor addition and dormers front and back. The owners wanted a high performing home that kept the heat in and the weather out.
Project information
On our first visit we found water getting in and a deteriorating roof, so the plan started at the top: replace and insulate the roof first, then transform the walls.
What we found
- The roof and dormers. The main tiled roof was near the end of its life. Both dormers drained badly, with water standing on the flat roofs and the front dormer falling back towards the main roof, risking rot.
- Dormers with almost no insulation. Under the old tile hanging there was only a little mineral wool between the studs. With just plasterboard and tiles between the rooms and the weather, the dormer rooms froze in winter and baked in summer.
- Solid brick walls. The original solid brick walls and parts of the ground floor extension had no insulation.
- Air quality. Sealing up the roof and walls without better ventilation would risk trapped humidity, stale air and condensation.
Phase 1: the roof, the dormers and ventilation
- A warm roof. We stripped the roof back to the timbers, fitted a warm roof insulation system over the rafters to give an unbroken layer across the top of the house without disturbing the rooms inside, and re-tiled the whole roof.
- The dormers. We re-formed the falls on both dormer roofs so rain runs off safely, finished them in durable EPDM, took off the old tile hanging, fitted rigid PIR board between the studs and added a layer of phenolic insulation over the frame, ready for render.
- Ventilation. A positive input ventilation unit keeps fresh, filtered air moving through the house, and humidistat controlled extract fans in the bathrooms deal with moisture automatically.
Phase 2: external wall insulation
We wrapped all the main walls in external wall insulation and finished them, and the insulated dormer faces, in a matching silicone render for a clean, contemporary look.
The outcome
A heat leaking dormer bungalow is now a fully wrapped, future proofed home. The warm roof, insulated dormers and external wall insulation seal the whole building against the weather and big swings in temperature.
The same bungalow, made new.
The front of the bungalow before the work, with its old roof and tile hung dormers, and after the new warm roof, insulated dormers and rendered walls.
Before
After
“The house looks completely transformed. Even with the work only recently completed, we've already noticed a massive difference in how consistent and balanced the indoor temperature feels. It kept the house wonderfully cool through a very hot summer, and now during these cooler autumn days, it holds the warmth effortlessly. Roll on winter, the house is all ready to go!”
What this project cost.
These are our published guide ranges for the work in this project, not the final invoice. Every house is different, so your own price comes from a survey.
A full whole house programme: a new warm roof, insulated dormers, external wall insulation and ventilation.
The individual measures behind that number
£20,000 to £32,000
£900 to £1,600
£250 including VAT, refunded against any work ordered
These are guide ranges for a typical Nottinghamshire property, including labour, materials and VAT. Insulation is currently zero rated for VAT until 31 March 2027. The warm roof, re-tiling and dormer work are priced per job once we can see the building.
Spread the cost over months, or over years.
Interest free credit over 12 months on orders up to £70,000, or fixed rate finance over three to five years. Applications go through Ideal4Finance, and you will see the full figures before you commit to anything.